Synonyms
1-CA 15-3
Special Instructions
Values obtained with different assay methods should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient’s course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please use the serial monitoring number 483404 to order.
This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.
Expected Turnaround Time
Within 1 day
Specimen Requirements
Specimen
Within 1 day
Volume
1 mL
Minimum Volume
0.7 mL (Note: This volume does not allow for repeat testing.)
Container
Gel-barrier tube (preferred) or red-top tube
Collection
If a red-top tube is used, transfer separated serum to a plastic transport tube.
Storage Instructions
Room temperature
Causes for Rejection
Citrate plasma specimen; improper labeling
Test Details
Use
Quantitative measurement of cancer antigen 15-3